<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Biotech AB</title>
	<atom:link href="http://www.biotech.se/ny/index.php?feed=rss2" rel="self" type="application/rss+xml" />
	<link>http://www.biotech.se/ny</link>
	<description>YOUR SINGLE PROVIDER OF HPLC AND FLUIDIC SCIENTIFIC PARTS &#38; ASSEMBLIES</description>
	<lastBuildDate>Thu, 19 Aug 2010 14:15:14 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
		<item>
		<title>Sapphire</title>
		<link>http://www.biotech.se/ny/?p=1000</link>
		<comments>http://www.biotech.se/ny/?p=1000#comments</comments>
		<pubDate>Thu, 19 Aug 2010 13:04:47 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Okategoriserade]]></category>

		<guid isPermaLink="false">http://www.biotech.se/ny/?p=1000</guid>
		<description><![CDATA[We are happy to add Sapphire Engineerings high precision pumps to our product range. Characteristics for the Sapphire pumps are very high precision and low cost of ownership. You can expect long life time and carefree usage. Application areas; Analytical Instrumentation, Biotechnology, Medical Equipment, Food &#38; Beverage   Founded in 1900, Sapphire Engineering has designed [...]]]></description>
			<content:encoded><![CDATA[<p style="TEXT-ALIGN: center"><a class="highslide" href="http://www.biotech.se/ny/wp-content/uploads/2010/08/Sapphire.jpg"><img class="aligncenter size-full wp-image-956" title="Sapphire Logga" src="http://www.biotech.se/ny/wp-content/uploads/2010/08/Sapphire.jpg" alt="Sapphire Logga" width="611" height="65" /></a></p>
<p>We are happy to add Sapphire Engineerings high precision pumps to our product range.</p>
<p>Characteristics for the Sapphire pumps are very high precision and low cost of ownership. You can expect long life time and carefree usage.</p>
<p>Application areas; Analytical Instrumentation, Biotechnology, Medical Equipment, Food &amp; Beverage</p>
<p> </p>
<p>Founded in 1900, Sapphire Engineering has designed and manufactured products from ultrahard materials, including sapphire, ruby, ceramics, and stainless steel for over 100 years. Acquired by the IDEX Corporation in 2004, Sapphire Engineering products are now a brand of IDEX Health &amp; Science LLC.</p>
<p> <a class="highslide" href="http://www.biotech.se/ny/wp-content/uploads/2010/08/Sapphire-IPV-2.jpg"><img class="size-full wp-image-1020 alignright" title="Sapphire IPV 2" src="http://www.biotech.se/ny/wp-content/uploads/2010/08/Sapphire-IPV-2.jpg" alt="Sapphire IPV 2" width="453" height="208" /></a></p>
<p> </p>
<h3><a href="http://www.biotech.se/ny/wp-content/uploads/2010/08/IPV-Integrated-Piston-Valve.pdf" target="_blank">IPV (Integrated Piston/Valve)</a></h3>
<p>Built on the same principles as our Precision Dispense Pumps, extensive tests show the IPV will outlast traditional syringes and valves by as much as 20-fold, yielding major lifetime cost savings. The IPV saves even more on downtime and upkeep because it requires no routine preventive maintenance such as cleaning and nut tightening, essential with conventional syringes. By selecting the seal-wash option, you can extend IPV life even longer when using it with difficult fluids.</p>
<p> </p>
<h3><a href="http://www.biotech.se/ny/wp-content/uploads/2010/08/VFP17-Dispense-Pump.pdf" target="_blank">VFP17 Precision Dispense Pump</a></h3>
<p>With its Zirconia Ceramic displacement piston technology, the VFP17 precision dispense pump offers several key benefits over competing displacement and syringe pumps, including:</p>
<ul>
<li>High precision and low cost of ownership</li>
<li>Expected pump life of millions of cycles</li>
<li>Available with total dispense volumes of 25 µL to 5 mL</li>
<li>Flexibility to customize pump head, piston and seal materials for your application</li>
</ul>
<p> </p>
<p> </p>
<h3><a href="http://www.biotech.se/ny/wp-content/uploads/2010/08/PVM-Pump-Valve-Module_V2.pdf" target="_blank">PVM (pump and valve module)</a></h3>
<p>The compact digital PVM (Pump and Valve Module) is a self-contained, stepper-motor-driven module. This product is designed for various liquid-handling applications such as automated pipetting, diluting, and dispensing. This unit is 100 percent compatible with the Cavro™ XP-3000 syringe pump, but uses a more robust, direct-drive leadscrew technology – not belts and pulleys.</p>
<p>The PVM uses the <a href="http://www.idex-hs.com/products/default.aspx?ProductID=2593">Sapphire Engineering™ IPV</a>, which meets and exceeds the precision and accuracy of traditional syringe/plug valve systems while offering up to 20x the life.</p>
<p> </p>
<p style="text-align: center;"><strong> </strong></p>
]]></content:encoded>
			<wfw:commentRss>http://www.biotech.se/ny/?feed=rss2&amp;p=1000</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Halo</title>
		<link>http://www.biotech.se/ny/?p=933</link>
		<comments>http://www.biotech.se/ny/?p=933#comments</comments>
		<pubDate>Fri, 15 Jan 2010 10:50:29 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Okategoriserade]]></category>

		<guid isPermaLink="false">http://www.biotech.se/ny/?p=933</guid>
		<description><![CDATA[   ♣ New short Fused-Core columns for ultrafast analysis – 20mm long  Now we offer the HALO columns also with 20mm length. This will enable even shorter analysis time with high resolution due to the Fused-Core technology. The 20mm columns are available with ID 2.1, 3.0 and 4.6mm. They are available with HALO C18, C8, [...]]]></description>
			<content:encoded><![CDATA[<p> <a class="highslide" href="http://www.biotech.se/ny/wp-content/uploads/2010/01/Halo.jpg"><img class="aligncenter size-full wp-image-937" title="Halo" src="http://www.biotech.se/ny/wp-content/uploads/2010/01/Halo.jpg" alt="Halo" width="658" height="77" /></a></p>
<p> <span style="color: #993300;">♣<strong> New </strong></span><strong><span style="color: #993300;">short Fused-Core columns for ultrafast analysis – 20mm lon</span><span style="color: #993300;">g</span></strong><strong></strong></p>
<p> Now we offer the HALO columns also with 20mm length. This will enable even shorter analysis time with high resolution due to the Fused-Core technology. The 20mm columns are available with ID 2.1, 3.0 and 4.6mm. They are available with HALO C18, C8, Phenyl-Hexyl, RP-Amide, and HILIC phases.</p>
<p>The HALO Fused-Core columns can be used in a standard HPLC system due to the low back pressure.</p>
<p><a href="http://www.biotech.se/ny/wp-content/uploads/2010/01/HALO-Dimensions-2010.pdf" target="_blank">See attached pdf file for a complete list of available dimensions.</a></p>
<p> <span style="color: #993300;">♣<strong> New </strong><strong>HALO Peptide ES-C18 for bio-separations</strong></span><strong></strong></p>
<p><strong> </strong>The new line of HALO columns has been specifically engineered to separate higher molecular weight compounds such as peptides and small proteins. These new columns contain advanced fused-core® particles that have bigger pores (160 Å versus 90 Å in standard HALO® particles), bonded with steric-protected C18 ligands to provide extra stability (ES) at low pH (&lt; 1) and high temperatures (up to 100ºC) which greatly expands the application range for HALO columns.</p>
<p>This new C18 bonded phase will offer additional separation selectivity to complement the existing HALO C18, C8, Phenyl-Hexyl, RP-Amide, and HILIC phases. <a href="http://www.biotech.se/ny/wp-content/uploads/2010/01/example_Halo_peptide_separations.pdf" target="_blank">Two examples of the ability of the new columns to provide excellent peak shape for larger molecules are shown in the attached pdf file.</a></p>
<p> HALO Peptide ES-C18 Specifications:</p>
<p>Stationary Phase Support</p>
<ul>
<li>2.7-micron diameter spherical, ultra-pure, “Type B” silica</li>
<li>1.7-micron solid core with a 0.5-micron porous silica layer fused to the surface</li>
<li>80 m<sup>2</sup>/gram surface area</li>
<li>160Å pore size</li>
</ul>
<p>Bonded Phase</p>
<ul>
<li>Steric-protected C18, octadecyldiisobutylsilane, 2.0 µmoles/m<sup>2</sup></li>
<li>No endcapping</li>
<li>pH range: 1 to 9</li>
<li>Maximum Temperature: 90ºC</li>
</ul>
<p>Maximum Pressure: 9,000 psi, 600 Bar</p>
<p><span style="color: #993300;"> <em>HALO &#8211; The name that defines a new direction in UHPLC</em></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.biotech.se/ny/?feed=rss2&amp;p=933</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Biotech AB provides every part of your fluidic system</title>
		<link>http://www.biotech.se/ny/?p=716</link>
		<comments>http://www.biotech.se/ny/?p=716#comments</comments>
		<pubDate>Wed, 23 Sep 2009 08:46:56 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Okategoriserade]]></category>

		<guid isPermaLink="false">http://www.biotech.se/ny/?p=716</guid>
		<description><![CDATA[KOT -  Knitted Open Tubular Reaction And Mixing Coils The KOT reactor is the Most Optimal Delay Element for use in Analytical Flow Systems By the knitting technique we use, the chromatographic peak shape will be preserved. Application areas for the KOT are for example post-column derivatization and as a delay in a system with [...]]]></description>
			<content:encoded><![CDATA[<h3 style="text-align: center;"><a href="http://www.biotech.se/ny/?page_id=790">KOT -  Knitted Open Tubular Reaction And Mixing Coils</a></h3>
<p><!-- br--></p>
<p style="text-align: left;">The KOT reactor is the Most Optimal Delay Element for use in Analytical Flow Systems</p>
<p>By the knitting technique we use, the chromatographic peak shape will be preserved. Application areas for the KOT are for example post-column derivatization and as a delay in a system with fraction collection. The KOT´s are made of inert PTFE and they are available as standard in lengths from 1-10 meters. Read more in the brochure below&#8230;</p>
<p style="text-align: center;"><a href="http://www.biotech.se/ny/wp-content/uploads/2009/09/Biotech-KOT-Brochure.pdf" target="_blank">Knitted Open Tubular Coils &#8211; Brochure</a></p>
<p style="text-align: center;"><a href="http://www.biotech.se/ny/wp-content/uploads/2008/11/untitled-2.png"><img class="aligncenter size-full wp-image-185" src="http://www.biotech.se/ny/wp-content/uploads/2008/11/untitled-2.png" alt="" width="600" height="50" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.biotech.se/ny/?feed=rss2&amp;p=716</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Smart Saver &#8211; save solvent with our new recycling unit</title>
		<link>http://www.biotech.se/ny/?p=698</link>
		<comments>http://www.biotech.se/ny/?p=698#comments</comments>
		<pubDate>Wed, 22 Jul 2009 14:11:46 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Okategoriserade]]></category>

		<guid isPermaLink="false">http://www.biotech.se/ny/?p=698</guid>
		<description><![CDATA[SmartSaver is a small, easy to use recycler which is USB driven.Save up to 90% of the solvent consumption in your analytical or semiprep isocratic LC-system. SmartSaver can be used with every LC-system on the market. It is shipped with tubing, fittings, USB cable, connection cables etc. Read more in the following pdf´s&#8230; USB Smart [...]]]></description>
			<content:encoded><![CDATA[<div class="mceTemp">
<p><a href="http://www.biotech.se/ny/?page_id=776"><img class="size-full wp-image-700 alignleft" title="SmartSaver" src="http://www.biotech.se/ny/wp-content/uploads/2009/07/SmartSaver.JPG" alt="SmartSaver - easy solvent recycling with your isocratic LC" width="120" height="160" /></a></p>
<p>SmartSaver is a small, easy to use recycler which is USB driven.Save up to 90% of the solvent consumption in your analytical or semiprep isocratic LC-system. SmartSaver can be used with every LC-system on the market. It is shipped with tubing, fittings, USB cable, connection cables etc.</p>
<p>Read more in the following pdf´s&#8230;</p>
<p><a href="http://www.biotech.se/ny/wp-content/uploads/2009/07/USB-Smart-Saver-Flyer.pdf" target="_blank">USB Smart Saver Flyer</a></p>
<p><a href="http://www.biotech.se/ny/wp-content/uploads/2009/07/SmartSaver-Operators-Manual.pdf" target="_blank">SmartSaver Operators Manual</a></p>
<p>Save solvent, money and environment&#8230; Contact us for information where you can buy our new recycler.</p>
<p><a href="http://www.biotech.se/ny/wp-content/uploads/2008/11/untitled-2.png"><img class="aligncenter size-full wp-image-185" src="http://www.biotech.se/ny/wp-content/uploads/2008/11/untitled-2.png" alt="" width="600" height="50" /></a></div>
]]></content:encoded>
			<wfw:commentRss>http://www.biotech.se/ny/?feed=rss2&amp;p=698</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Degassing News From Biotech</title>
		<link>http://www.biotech.se/ny/?p=693</link>
		<comments>http://www.biotech.se/ny/?p=693#comments</comments>
		<pubDate>Mon, 20 Jul 2009 14:46:49 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Okategoriserade]]></category>

		<guid isPermaLink="false">http://www.biotech.se/ny/?p=693</guid>
		<description><![CDATA[We are proud to announce that we can now offer an upgrade for your current 1100 degasser with the latest technology! Buy our kit and do the upgrade by yourself within 20 minutes! Read more&#8230;]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;">We are proud to announce that we can now offer an upgrade for your current 1100 degasser with the latest technology!</p>
<p style="text-align: center;">Buy our kit and do the upgrade by yourself within 20 minutes!</p>
<p style="text-align: center;">
<p style="text-align: center;"><img class="size-full wp-image-145 aligncenter" title="1100 Degasser" src="http://www.biotech.se/ny/wp-content/uploads/2009/01/degasser.png" alt="Agilent Degasser" width="600" height="178" /></p>
<h3 style="text-align: center;"><a href="http://www.biotech.se/ny/wp-content/uploads/2008/11/1100-Degasser-Upgrade.pdf"><span style="color: #000080;">Read more</span></a><span style="color: #000080;">&#8230; </span><img class="aligncenter size-full wp-image-185" title="untitled-2" src="http://www.biotech.se/ny/wp-content/uploads/2008/11/untitled-2.png" alt="untitled-2" width="600" height="50" /></h3>
]]></content:encoded>
			<wfw:commentRss>http://www.biotech.se/ny/?feed=rss2&amp;p=693</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New HALO™ columns for extremely rapid and efficient separations</title>
		<link>http://www.biotech.se/ny/?p=149</link>
		<comments>http://www.biotech.se/ny/?p=149#comments</comments>
		<pubDate>Wed, 15 Jul 2009 20:56:52 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Okategoriserade]]></category>

		<guid isPermaLink="false">http://www.biotech.se/ny/?p=149</guid>
		<description><![CDATA[- HALO™ Phenyl-Hexyl is the latest addition in the unique HALO series of UHPLC  columns. This new stationary phase gives alternate selectivity, especially for compounds containing aromatic groups. Excellent stability and minimum bleed for LC-MS applications. Base deactiveated for good peak shape when separating basic compounds. Moderate back pressure allows for UHPLC-like perfromance with conventional HPLC equipment. [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;"><img class="size-full wp-image-152 aligncenter" title="halo" src="http://www.biotech.se/ny/wp-content/uploads/2008/12/halo.jpg" alt="halo" width="624" height="80" /></p>
<p style="text-align: left;"><span style="color: #ff0000;"><strong>- HALO<span style="line-height: 15px;">™</span> Phenyl-Hexyl</strong> is the latest addition in the unique HALO series of UHPLC  columns. This new stationary phase gives alternate selectivity, especially for compounds containing aromatic groups.</span></p>
<ul>
<li><span style="color: #ff0000;">Excellent stability and minimum bleed for LC-MS applications.</span></li>
</ul>
<ul>
<li><span style="color: #ff0000;">Base deactiveated for good peak shape when separating basic compounds.</span></li>
</ul>
<ul>
<li><span style="color: #ff0000;">Moderate back pressure allows for UHPLC-like perfromance with conventional HPLC equipment.</span></li>
</ul>
<p style="text-align: left;">- HALO<span class="style_1" style="line-height: 15px;">™</span> RP-Amide, new stationary phase for different selectivity and improved retention of polar compounds</p>
<p style="text-align: left;">- HALO<span class="style_1" style="line-height: 15px;">™</span> HILIC, new stationary phase for separation of very polar compounds</p>
<p style="text-align: left;">- New dimensions; HALO<span class="style_1" style="line-height: 15px;">™</span> C18 now available with ID 1mm</p>
<p style="text-align: left;">- Capillary columns; HALO<span class="style_1" style="line-height: 15px;">™</span> C18 and C8 now available with ID 75, 100, 200 and 300µm</p>
<p style="text-align: center;"><a href="http://www.biotech.se/ny/?page_id=393" target="_self">Read more&#8230;</a></p>
<p style="text-align: center;"><img class="aligncenter size-full wp-image-185" src="http://www.biotech.se/ny/wp-content/uploads/2008/11/untitled-2.png" alt="" width="600" height="50" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.biotech.se/ny/?feed=rss2&amp;p=149</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Biotech USA / Official Inauguration</title>
		<link>http://www.biotech.se/ny/?p=173</link>
		<comments>http://www.biotech.se/ny/?p=173#comments</comments>
		<pubDate>Mon, 08 Sep 2008 22:22:40 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Okategoriserade]]></category>

		<guid isPermaLink="false">http://www.biotech.se/ny/?p=173</guid>
		<description><![CDATA[We have had the official ribbon-cutting for our subsidiary Biotech USA to be located at the below address: Biotech USA 281 County Rd C2W Roseville  MN 55113 Telephone: 651-486-7678 Cell Phone:651-271-3010 Contact : Mr Mark Storkamp, Manager Purpose of the new office is to actively promote our line of Degassers and Debubblers in North America. [...]]]></description>
			<content:encoded><![CDATA[<p>We have had the official ribbon-cutting for our subsidiary Biotech USA to be located at the below address:</p>
<p>Biotech USA<br />
281 County Rd C2W<br />
Roseville  MN 55113<br />
Telephone: 651-486-7678<br />
Cell Phone:651-271-3010<br />
Contact : Mr Mark Storkamp, Manager</p>
<p>Purpose of the new office is to actively promote our line of Degassers and Debubblers in North America. In addition, the office will provide end-users and OEM;s with a broad range of components which are commonly used to support HPLC, Flow Injection Analysis and related techniques.</p>
<p>Mark Storkamp who has 15 years of experience in the development and support of degassers can be reached at the above telephone numbers.</p>
<p>You can also reach Mark at email: <a href="mailto:mstorkamp@biotechusa.us">mstorkamp@biotechusa.us</a></p>
<p style="text-align: center;"><img class="aligncenter size-full wp-image-185" src="http://www.biotech.se/ny/wp-content/uploads/2008/11/untitled-2.png" alt="" width="600" height="50" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.biotech.se/ny/?feed=rss2&amp;p=173</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Biotech AB proudly introduce the new Rheodyne™ MX II Valves</title>
		<link>http://www.biotech.se/ny/?p=178</link>
		<comments>http://www.biotech.se/ny/?p=178#comments</comments>
		<pubDate>Fri, 12 Oct 2007 22:26:47 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Okategoriserade]]></category>

		<guid isPermaLink="false">http://www.biotech.se/ny/?p=178</guid>
		<description><![CDATA[Automated Valve Solutions – from 9 bar up to 1 000 bar Rheodyne™ MX Series II™ automated fluidic valves provide productivity enhancing solutions for today’s demanding analytical methods. Combine MX Series II modular valves with your current instrument to support complex fluid switching, sample injection needs, method development etc. Read more&#8230;]]></description>
			<content:encoded><![CDATA[<p class="Heading_1"><strong><span class="style_17" style="line-height: 14px;">Automated Valve Solutions</span><img class="alignright size-full wp-image-177" title="mx-series-ii-group-1" src="http://www.biotech.se/ny/wp-content/uploads/2009/01/mx-series-ii-group-1.jpg" alt="mx-series-ii-group-1" width="320" height="182" /><br />
<span class="style_17" style="line-height: 14px;">– from 9 bar up to 1 000 bar</span></strong></p>
<p class="Heading_1"><span class="style_16" style="line-height: 14px;">Rheodyne</span><span class="style_1" style="line-height: 15px;">™</span><span class="style_16" style="line-height: 14px;"> MX Series II™ automated fluidic valves provide productivity enhancing solutions for<br />
</span></p>
<p class="Heading_1"><span class="style_16" style="line-height: 14px;">today’s demanding analytical methods. Combine MX Series II modular valves with your current<br />
</span></p>
<p><span class="style_16" style="line-height: 14px;">instrument to support complex fluid switching, sample injection needs, method development etc.</span></p>
<p style="text-align: center;"><span class="style_16" style="line-height: 14px;"><img class="aligncenter size-full wp-image-185" src="http://www.biotech.se/ny/wp-content/uploads/2008/11/untitled-2.png" alt="" width="600" height="50" /><br />
</span></p>
<p style="text-align: center;"><span class="style_16" style="line-height: 14px;"><a href="http://www.biotech.se/ny/?page_id=451" target="_self">Read more&#8230;</a></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.biotech.se/ny/?feed=rss2&amp;p=178</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New Frit brochure from Biotech</title>
		<link>http://www.biotech.se/ny/?p=196</link>
		<comments>http://www.biotech.se/ny/?p=196#comments</comments>
		<pubDate>Tue, 31 Jul 2007 23:17:34 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Okategoriserade]]></category>

		<guid isPermaLink="false">http://www.biotech.se/ny/?p=196</guid>
		<description><![CDATA[Frits for analytical, semi-preparative and preparative chromatography.        Read more&#8230;]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;"><span class="style_16" style="line-height: 14px;">Frits for analytical, semi-preparative and preparative chromatography.</span></p>
<p style="text-align: center;"><span class="style_16" style="line-height: 14px;"><img class="size-full wp-image-195 aligncenter" title="HPLC Frits" src="http://www.biotech.se/ny/wp-content/uploads/2009/01/shapeimage_5.jpg" alt="shapeimage_5" width="225" height="175" /></span></p>
<p style="text-align: center;"> </p>
<p style="text-align: center;">   </p>
<p style="text-align: center;"> <a href="http://www.biotech.se/ny/?page_id=434" target="_self">Read more&#8230;</a><img class="size-full wp-image-185  aligncenter" src="http://www.biotech.se/ny/wp-content/uploads/2008/11/untitled-2.png" alt="" width="600" height="50" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.biotech.se/ny/?feed=rss2&amp;p=196</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Latest NEWS!!! No more problems with bubbles</title>
		<link>http://www.biotech.se/ny/?p=192</link>
		<comments>http://www.biotech.se/ny/?p=192#comments</comments>
		<pubDate>Tue, 31 Jul 2007 23:10:34 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Okategoriserade]]></category>

		<guid isPermaLink="false">http://www.biotech.se/ny/?p=192</guid>
		<description><![CDATA[Biotech AB proudly presents a new DEBUBBLER for removal of bubbles in liquids.   Read more&#8230;]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;"><span class="style_16" style="line-height: 14px;">Biotech AB proudly presents a new DEBUBBLER for removal of bubbles in liquids.</span></p>
<p style="text-align: center;"><span class="style_16" style="line-height: 14px;"><img class="size-full wp-image-193 aligncenter" src="http://www.biotech.se/ny/wp-content/uploads/2009/01/shapeimage_8.jpg" alt="" width="228" height="235" /></span></p>
<p> </p>
<p style="text-align: center;"><a href="http://www.biotech.se/ny/?page_id=422" target="_self">Read more&#8230;</a></p>
<p style="text-align: center;"><img class="aligncenter size-full wp-image-185" src="http://www.biotech.se/ny/wp-content/uploads/2008/11/untitled-2.png" alt="" width="600" height="50" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.biotech.se/ny/?feed=rss2&amp;p=192</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
